| Range of product |
Square D Pumptrol |
| Pressure sensor name |
9013FH |
| Pressure sensor size |
150 psi |
| Value of setting |
Off at 125 psi |
| Electrical circuit type |
Power circuit |
| Product specific application |
Control small electrically driven air compressors |
| Quantity per set |
1 |
| Type of packing |
Individual |
| Pressure sensor type |
Electromechanical pressure switch |
| Controlled fluid |
Air (-22...257 °F) |
| Adjustable range on rising pressure |
70...150 psi |
| Approximate adjustable differential |
30 psi |
| Destruction pressure |
220 psi |
| Pressure actuator |
Diaphragm |
| Pressure switch type of operation |
Regulation between 2 thresholds |
| Scale type |
Fixed differential |
| Setting |
Internal |
| Local display |
Without |
| Contacts type and composition |
2 NC, snap action, DPST-DB, Form YY |
| Cable entry number |
2 0.88 in cable entries with 0.84 in across flats UL 508 |
| Electrical connection |
Screw-clamp terminals, clamping capacity: 5.261 mm² Screw-clamp terminals, clamping capacity: 10 AWG |
| Fluid connection type |
0.25 inch NPSF internal conforming to UL 508 |
| Short circuit protection |
20 A by cartridge fuse, type gG |
| Materials in contact with fluid |
Nitrile (Buna-N) or equivalent rubber diaphragm Zinc plated steel or equivalent flange |
| Material |
Noryl thermoplastic resin or equivalent cover Polypropylene cover |
| Operating position |
Any position |
| Motor power kW |
0.75 kW (1 hp) at 575 V AC, 3 phases 0.75 kW (1 hp) at 460 V AC, 3 phases 2.2 kW (3 hp) at 230 V AC, 3 phases 1.5 kW (2 hp) at 115 V AC, 3 phases 1.1 kW (1.5 hp) at 115 V AC, 1 phase 1.5 kW (2 hp) at 230 V AC, 1 phase |
| Electrical durability |
100000 cycles at 10 cyc/mn |
| Mechanical durability |
300000 cycles |
| Terminal block type |
4 terminals |
| Operating rate |
10 cyc/mn |
| [Ui] rated insulation voltage |
575 V conforming to UL 508 |
| Product weight |
1 lb(US) |
| Repeat accuracy |
+/- 3 % |
| Terminals description ISO n°1 |
L1-T1 L2-T2 |
| Width |
3.1 in |
| Height |
3.71 in |
| Depth |
3.76 in |
| Factory modification |
2-way pressure release valve Maintained manual cut-out lever (AUTO-OFF) |
| Standards |
CE UL 508 |
| Ambient air temperature for operation |
-33...257 °F |
| Ambient air temperature for storage |
-33...257 °F |
| Protective treatment |
None |
| NEMA degree of protection |
NEMA 1 conforming to UL 50 |
| IP degree of protection |
IP20 conforming to IEC 60529 |
| Product certifications |
UL listed file E12158 CSA file LR25490 |